纤维素气凝胶在建筑节能领域中的应用研究进展
刘荷, 赵石磊, 刘赋瑶, 马军, 白媛, 樊威

Applications of cellulose aerogel in building energy efficiency field
LIU He, ZHAO Shilei, LIU Fuyao, MA Jun, BAI Yuan, FAN Wei
表1 节能建筑领域纤维素气凝胶材料性能
Tab.1 Properties of cellulose aerogel in energy-efficient buildings
材料 热导率/
(W·m-1·K-1)
水接
触角/(°)
极限氧
指数/%
CellA[41] 0.017~0.029 >150 —
DPW[42] 0.033~0.065 — —
BNNS-g/CNF[43] 0.052 — 36.0
TMLA[44] 0.028 — 38.6
NFC-Si-T[45] 0.028~0.049 — 42.6~51
LG70[46] 0.023 — 30.1
CL-A@PD[47] 0.021~0.029 137 36.5
SRA[48] 径向0.030
轴向0.056
横截面164
径截面156
—
CNF aerogel[49] 0.026 140.3 —
HSCA[50] 0.038 151.4 —
MBC/LDH[51] 0.034 142 34.1
M-T@CNF/PVA[53] 0.155 — —
SiO2-PCC/GEL-HEC[54] 0.049 152.3 —
HNFA[56] 0.028 146 —
GFRA[57] 0.029~0.042 115~120 31.5~34.5
PVA-GA-CNF[58] 0.044 — —
3PM2G[59] 0.047 — 73
Cell/SiO2[60] 0.034 158.72 —
SC/BC@AS[61] — 133.58 —
CNF/BP[62] 0.067 — 20.6