针对人体在高温或高寒环境中长时间工作可能导致中暑、热痉挛、低体温症等疾病的问题,在介绍人体体温调节基本原理和换热机制的基础上,着重介绍了利用制冷或制热空调服对人体体温进行主动调节的基本原理,同时归纳和总结了现阶段各类制冷制热空调服的工作原理,并比较了其优缺点。在制冷空调服领域,着重介绍了空气冷却、相变冷却、冰袋冷却、液体冷却等主被动降温方法;在制热空调服领域,着重介绍了电热、相变制热、化学制热等方法。在空调服未来的发展方向上,伴随可穿戴技术的发展,提出了可穿戴技术与空调服结合应用的新构想,对同时具有生命体征监测和体温调节功能的新型空调服进行了展望。

关键词: 空调服, 可穿戴技术, 体温调节, 着装舒适性

Abstract:

Based on the problems that person working in the extremely hot or cold environment may suffer from injuries like heat strke, heat cramps and hypothermia, the basic principle of human thermal regulation was reviewed, and the advantages and disadvantages were compared. On the aspect of personal cooling garments, the air cooling, phase change microcapsule (PCM) cooling, ice pack cooling and liquid cooling method were introduced. For the personal heating garments, the electrical heating, PCM heating, and chemical heating method were introduced. Based on the current research trend, the outlook for the emerging trend of personal garments and wearable technologies were also discussed. A new type of personal cool/heating garment which is integrated with life monitoring function was also proposed.

Key words: heating/cooling garment, wearable technology, human thermal regulation, clothing comfort

[1] 王美红, 鞠小宁, 周庆博, 孙琳, 尚伟, 许继平, et al., "热射病致神经系统损害9例临床分析," 中国神经精神疾病杂志, pp. 460-465, 2015. [2] 陈艳 and 顾香, "热痉挛1例报告," 现代医药卫生, pp. 1119-1120, 2015. [3] 骆海山 and 步金星, "常温下10公里负重跑致热衰竭4例," 中国保健营养, vol. 26, pp. 506-506, 2016. [4] 潘树义, 郭大志, 杨晨, 肖宏, 张军, and 金国荣, "低温症的研究现状和高压氧治疗应用前景分析," 中华航海医学与高气压医学杂志, vol. 22, pp. 76-78, 2015. [5] S. M. Keim, J. A. Guisto, and S. J. Jr, "Environmental thermal stress," Annals of Agricultural & Environmental Medicine Aaem, vol. 9, p. 1, 2002. [6] K. Parsons, "Human Thermal Environments," Crc Press, vol. 18, pp. 67-68, 2003. [7] B. W. Zingano, "A discussion on thermal comfort with reference to bath water temperature to deduce a midpoint of the thermal comfort temperature zone," Renewable Energy, vol. 23, pp. 41-47, 2001. [8] G. Havenith, "Interaction of Clothing and Thermoregulation," Exogenous Dermatology, vol. 1, pp. 221-230, 2002. [9] L. I. Crawshaw, E. R. Nadel, J. A. Stolwijk, and B. A. Stamford, "Effect of local cooling on sweating rate and cold sensation," Pflügers Archiv European Journal of Physiology, vol. 354, pp. 19-27, 1975. [10] B. Conger and J. Makinen, "High Performance Torso Cooling Garment," 2016. [11] Y. T. Ku, L. D. Montgomery, and B. W. Webbon, "Hemodynamic and thermal responses to head and neck cooling in men and women," American Journal of Physical Medicine & Rehabilitation, vol. 75, p. 443, 1996. [12] 杨帆 and 廉璐, "将半导体制冷应用于空调服的可行性分析," 建材发展导向:下, vol. 14, 2016. [13] Y. Yang, J. Stapleton, B. T. Diagne, G. P. Kenny, and C. Q. Lan, "Man-portable personal cooling garment based on vacuum desiccant cooling," Applied Thermal Engineering, vol. 47, pp. 18-24, 2012. [14] Y. Yang, D. Rana, C. Q. Lan, and T. Matsuura, "Development of Membrane-Based Desiccant Fiber for Vacuum Desiccant Cooling," Acs Appl Mater Interfaces, vol. 8, pp. 15778-15787, 2016. [15] T. M. Mclellan, "The Efficacy of an Air-Cooling Vest to Reduce Thermal Strain for Light Armour Vehicle Personnel," 2007. [16] A. Eldad, A. Y. Salmon, S. Breiterman, M. Chaouat, and H. Benbassat, "Flame burn protection: assessment of a new, air-cooled fireproof garment," Military Medicine, vol. 168, pp. 595-9, 2003. [17] 曾彦彰, 邓中山, and 刘静, "基于微型风扇阵列系统的人体降温空调服," 纺织学报, vol. 28, pp. 100-105, 2007. [18] M. Zhao, C. Gao, F. Wang, K. Kuklane, I. Holmér, and J. Li, "A study on local cooling of garments with ventilation fans and openings placed at different torso sites," International Journal of Industrial Ergonomics, vol. 43, pp. 232-237, 2013. [19] T. M. Mcleilan, "Cooling Options for Shipboard Personnel Operating in Hot Environments," Cooling Options for Shipboard Personnel Operating in Hot Environments, 2002. [20] G. P. Kenny, A. R. Schissler, J. Stapleton, M. Piamonte, K. Binder, A. Lynn, et al., "Ice cooling vest on tolerance for exercise under uncompensable heat stress," Journal of Occupational & Environmental Hygiene, vol. 8, p. 484, 2011. [21] P. A. Bishop, "Effects of a Novel Ice-Cooling Technique on Work in Protective Clothing at 28°C, 23°C, and 18°C WBGTs," American Industrial Hygiene Association Journal, vol. 60, pp. 96-104, 1999. [22] G. Bartkowiak, A. D?browska, and A. Marsza?ek, "Analysis of thermoregulation properties of PCM garments on the basis of ergonomic tests," Textile Research Journal, vol. 83, pp. 148-159, 2012. [23] P. Feliński and R. Sekret, "Experimental study of evacuated tube collector/storage system containing paraffin as a PCM," Energy, vol. 114, pp. 1063-1072, 2016. [24] R. S. Andriamitantsoa, W. Dong, H. Gao, and G. Wang, "PEG encapsulated by porous triamide-linked polymers as support for solid-liquid phase change materials for energy storage," Chemical Physics Letters, vol. 671, pp. 165-173, 2017. [25] C. Alkan, A. Sari, and O. Uzun, "Poly(ethylene glycol)/acrylic polymer blends for latent heat thermal energy storage," Aiche Journal, vol. 52, pp. 3310-3314, 2010. [26] M. Mokhtari Yazdi and M. Sheikhzadeh, "Personal cooling garments: a review," The Journal of The Textile Institute, vol. 105, pp. 1231-1250, 2014. [27] B. Pause, "Textiles with improved thermal capabilities through the application of Phase Change Material (PCM) microcapsules," 2000. [28] B. A. Ying, Y. L. Kwok, Y. Li, Q. Y. Zhu, and C. Y. Yeung, "Assessing the performance of textiles incorporating phase change materials," Polymer Testing, vol. 23, pp. 541-549, 2004. [29] S. Yazdanirad and H. Dehghan, "Designing of the Cooling Vest from Paraffin Compounds and Evaluation of its Impact Under Laboratory Hot Conditions," International Journal of Preventive Medicine, vol. 7, p. 47, 2016. [30] R. A. SCOTT, "The technology of electrically heated clothing," Ergonomics, vol. 31, pp. 1065-1081, 1988. [31] C. L. Butts, C. R. Smith, M. S. Ganio, and B. P. McDermott, "Physiological and perceptual effects of a cooling garment during simulated industrial work in the heat," Appl Ergon, vol. 59, pp. 442-448, Mar 2017. [32] C. A. Sayed, L. Vinches, and S. Hallé, "Towards Optimizing a Personal Cooling Garment for Hot and Humid Deep Mining Conditions," Open Journal of Optimization, vol. 05, pp. 35-43, 2016. [33] J. H. Kim, A. Coca, W. J. Williams, and R. J. Roberge, "Effects of liquid cooling garments on recovery and performance time in individuals performing strenuous work wearing a firefighter ensemble," J Occup Environ Hyg, vol. 8, pp. 409-16, Jul 2011. [34] E. A. Beenakker, T. I. Oparina, A. Hartgring, A. Teelken, A. V. Arutjunyan, and K. J. De, "Cooling garment treatment in MS: clinical improvement and decrease in leukocyte NO production," Neurology, vol. 57, pp. 892-4, 2001. [35] J. K. Westin, J. S. Kapat, and L. C. Chow, "An Improved Thermoregulatory Model for Automatic Cooling Control Development in Liquid Cooling Garment Systems," Journal of Thermal Science and Engineering Applications, vol. 2, p. 011002, 2010. [36] T. Wang, L. Wang, L. Bai, G. Lin, X. Bu, X. Liu, et al., "Experimental study on the performance of a liquid cooling garment with the application of MEPCMS," Energy Conversion and Management, vol. 103, pp. 943-957, 2015. [37] A. Morriesen, "Personal Cooling System Based on Vapor Compression Cycle for Stock Car Racing Drivers," 2012. [38] B. S. Cadarette, L. Levine, M. A. Kolka, G. N. Proulx, M. M. Correa, and M. N. Sawka, "Heat strain reduction by ice-based and vapor compression liquid cooling systems with a toxic agent protective uniform," Aviation Space & Environmental Medicine, vol. 73, p. 665, 2002. [39] G. Bartkowiak, A. Dabrowska, and A. Marszalek, "Assessment of an active liquid cooling garment intended for use in a hot environment," Appl Ergon, vol. 58, pp. 182-9, Jan 2017. [40] A. D. Flouris and S. S. Cheung, "Design and Control Optimization of Microclimate Liquid Cooling Systems Underneath Protective Clothing," Annals of Biomedical Engineering, vol. 34, pp. 359-372, 2006. [41] S. N. Cheuvront, M. A. Kolka, B. S. Cadarette, S. J. Montain, and M. N. Sawka, "Efficacy of intermittent, regional microclimate cooling," Journal of Applied Physiology, vol. 94, p. 1841, 2003. [42] 唐虹, 施耘, and 曲年震, "职业性手指急性深度冻伤的早期减张治疗," 中华劳动卫生职业病杂志, vol. 34, pp. 457-458, 2016. [43] 康思宁, 吴斗, 刘强, and 徐彬, "综合治疗透水矿难幸存者"浸渍足"28例," 中华创伤杂志, vol. 27, pp. 581-582, 2011. [44] M. R. Sury and S. Scuplak, "Water-filled garment warming of infants undergoing open abdominal or thoracic surgery," Pediatr Surg Int, vol. 22, pp. 182-5, Feb 2006. [45] E. L. Wilkins and G. Havenith, "External heating garments used post-warm-up improve upper body power and elite sprint swimming performance," Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering & Technology, 2016. [46] E. Pang, S. Pickering, A. Chan, and K. Wong, "Use of recycled carbon fibre as a heating element," Journal of Composite Materials, vol. 47, pp. 2039-2050, 2013. [47] A. Elgafy and S. Mishra, "A heat transfer model for incorporating carbon foam fabrics in firefighter’s garment," Heat & Mass Transfer, vol. 50, pp. 545-557, 2014. [48] V. Koncar, C. Cochrane, M. Lewandowski, F. Boussu, and C. Dufour, "Electro‐conductive sensors and heating elements based on conductive polymer composites," International Journal of Clothing Science & Technology, vol. 21, pp. 82-92, 2011. [49] G. D. Mey, M. ?z?elik, A. Schwarz, I. Kazani, C. Hertleer, L. V. Langenhove, et al., "Designing of conductive yarn knitted thermal comfortable shirt using battery operated heating system," Tekstil Ve Konfeksiyon, vol. 24, pp. 26-29, 2014. [50] R. Deloire and J. Durand, "HEATING GARMENT," ed: US, 1973. [51] L. Hao, Z. Yi, C. Li, X. Li, W. Yuxiu, and G. Yan, "Development and characterization of flexible heating fabric based on conductive filaments," Measurement, vol. 45, pp. 1855-1865, 2012. [52] 李峻, 李灵炘, 曹霄洁, and 刘晓刚, "碳纤维发热服装设计的研究," 纺织报告, pp. 48-51, 2007. [53] J. Rantanen, T. Karinsalo, A. Reho, M. M?kinen, P. Talvenmaa, M. Tasanen, et al., Smart Clothing for the Arctic Environment, 2000. [54] K. L. Brekkestran, K. Aghai-Tabriz, N. N. Nguyen, and B. D. Batcheller, "Electronic control system and method for cold weather garment," ed: US, 1992. [55] N. Sarier and E. Onder, "The manufacture of microencapsulated phase change materials suitable for the design of thermally enhanced fabrics," Thermochimica Acta, vol. 452, pp. 149-160, 2007. [56] C. Y. L. Chan and D. R. Burton, "Local heating source for shallow water divers ☆," Journal of Power Sources, vol. 6, pp. 291-304, 1981. [57] J. J. Simmons, J. Simmons, and S. Simmons, "Heated vest with pouches for accommodating inserted heating packets," ed: US, 1994.

[1] 王栋 卿星 蒋海青 钟卫兵 李沐芳. 纤维材料与可穿戴技术的融合与创新[J]. 纺织学报, 2018, 39(05): 150-154.
[2] 杨晨啸 李鹂. 柔性智能纺织品与功能纤维的融合[J]. 纺织学报, 2018, 39(05): 160-169.
[3] 许静娴 李俊 刘慧娟 王云仪. 热调节暖体假人在着装舒适性评价中的应用现状[J]. 纺织学报, 2017, 38(07): 164-172.
[4] 严妮妮 张辉 邓咏梅. 可穿戴医疗监护服装研究现状与发展趋势[J]. 纺织学报, 2015, 36(06): 162-0.
[5] 张向辉;王云仪;李俊;张文斌. 防护服装结构设计对着装舒适性的影响[J]. 纺织学报, 2009, 30(06): 138-144.
[6] 曾彦彰;邓中山;刘静.. 基于微型风扇阵列系统的人体降温空调服[J]. 纺织学报, 2007, 28(6): 100-105.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!